Fascia iliaca / PENG block ultrasound phantom
Ultrasound-guided regional anesthesia (fascia iliaca and PENG blocks) · CC BY-NC-SA 4.0 · Working group contribution, October 2026
DIY ultrasound-guided nerve block phantom built around a 3D-printed hemipelvis, developed and tested with residents in October 2026 and shared with the Med Annex working group. Full write-up with print files is pending as a book appendix; this page preserves the build so it can be reproduced now.
Bill of materials
- 3D-printed hemipelvis (anterior half only; cut the model, the posterior half is not needed under the probe)
- Ballistic gelatin: per batch, 100 g gelatin + 900 mL water + 20 g flour (flour or cornstarch gives tissue-like echogenicity; ratios from published simulation literature)
- 550 cord strands for nerve bundles
- Surgical tubing for vessels, filled with water, ends sealed with printed plugs (hot glue will not bond inside the tubing)
- Plastic wrap (Saran) for fascial planes
- A basin to cast in
Build sequence
- Print the hemipelvis, place in the basin, and pour gelatin to half depth.
- Lay 550 cord strands as nerve bundles. Free them from the first gelatin layer once it sets, so they move when anesthetic is injected beneath them.
- Place water-filled surgical tubing as vessels, plugged at both ends with printed plugs.
- Lay three layers of plastic wrap across the model as the fascia iliaca, then pour the next gelatin layer.
- Lay three more layers of wrap as the fascia lata, then pour the final layer.
Observed performance
Worked: - Residents got a reasonable ultrasound view of AIIS, superior pubic ramus, fascial layers, and vessels. - PLA reads echodense, as bone should. - The wrap layers dissected realistically under injection, showing anesthetic spread along the fascial plane.
Needs work: - Tactile feedback was not fully realistic; try a lower gelatin density. - Fascial layers need to be thicker to give a felt "pop" on puncture (the blind version of this block depended on that feel), while staying flexible enough to conform to the model surface. - Surgical tubing is more echoreflective than real vessels, filled or not. Good enough as placeholders; other tubing types worth trying.
Status
Print files (cut hemipelvis, tubing plugs) not yet uploaded. Credit: working group contribution; named attribution to follow with the author's OK.